Shelly Qubino Wave 1 transforms any switch or electrical contact into a smart one
Shelly Qubino Wave 1 transforms any switch or electrical contact into a smart one
Код | S3800235269039 |
Код производителя | 3800235269039 |
Наличие | 8 шт. |
Предполагаемый срок отправки | 1-2 рабочих дней |
20000+ Успешных доставок по всему миру
Стоимость доставки со склада в Таллинне0% VAT для Европейских компаний или клиентов вне Евросоюза
Система автоматически формирует заказы с 0% VAT при соблюдении условийВозможность возврата
14 дней на возврат оборудованияWave 1 (EU)
Device identification
Device: Wave 1 (EU)
EU Part number/Ordering Code: QNSW-001X16EU
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0083
Z-Wave Manufacturer: Shelly Europe
Z-Wave Manufacturer ID: 0x0460
Terminology
-
Device - In this document, the term “Device” is used to refer to the Shelly Qubino device that is a subject of this guide.
-
Gateway (GW) - A Z-Wave™ gateway, also referred to as a Z-Wave™ controller, Z-Wave™ main controller, Z-Wave™ primary controller, or Z-Wave™ hub, etc., is a device that serves as a central hub for a Z-Wave™ smart home network. The term “gateway” is used in this document.
-
S button - The Z-Wave™ Service button, located on Z-Wave™ devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
Short description
The Device controls on/off function for one electrical appliance, e.g., bulb, ceiling fan, IR heater, electrical locks, garage doors, irrigation system, etc. The output contact is potential-free (dry contact), so different power supply loads (up to 16 A) can be connected to the Device. It is compatible with push-buttons and switches (default).
Switch/push-button connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state - on, off, on, etc. If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button will change the output O (O1) state to the opposite state - on, off, on, etc.
Switch connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output O (O1) state to the opposite state - on, off, on, etc.
-
Change switch position once: Change the state of the output O (O1) state to the opposite state and send the command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association).
Switch-memory connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch-memory, than:
-
Switching to Close switch-memory contact: Change the state of the output state O (O1) to the On state and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
-
Switching to Open switch-memory contact: Change the state of the output state O (O1) to the Off state and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
Push-button connected to input terminal SW (SW1)
If the SW (SW1) is configured as a push-button in the Device settings, each press of the push-button changes the output state O (O1) to opposite - ON, OFF, ON, etc.
-
1x click: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
-
2x click: If the delay between first in second click is less then 500ms, this is interpreted as double clik. Send command to the associated devices (dimmers, shutters,….) in associated groups 2 and 3 (check chapter Z-Wave Association)
-
Hold: Send command to the associated devices in associated group 3 (check chapter Z-Wave Association)
-
Release: Send command to the associated devices in associated group 3 (check chapter Z-Wave Association)
Main applications
-
Residential
-
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
-
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
-
Government/municipal
-
University college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave®.
This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.
To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.
Simplified internal schematics
Device electrical interfaces
Inputs
-
1 switch/push-button input on screw terminal
-
1 potential-free contact relay input on screw terminal
-
3 power supply inputs on screw terminals: N (+), L (Ʇ) and 12V
Outputs
-
1 potential-free contacts relay output on screw terminal
Connectivity
Z-Wave - Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety features
Overheat protection
-
switch off its own relay
-
sends the Notification Report to the Gateway (Overheat detected)
-
the led lights react as specified above (check blinking mode for Overheat detected)
Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.
Supported load types
-
Resistive (incandescent bulbs, heating devices)
-
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
-
Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User interface
S button and operating modes
-
Settings mode:
Is required to start the desired procedure, for example: adding (inclusion), removing (exclusion), factory reset, etc. It has a limited operating time. After completing the procedure in Setting mode, the Device automatically switches to Normal mode.
-
Entering Setting mode:
-
Press and hold the S button on the Device until the LED turns solid blue.
-
An additional quick press on the S button changes the menu in an infinite loop.
-
The Menu LED status has a timeout of 10s before entering again into Normal mode.
-
S button’s functions
-
Manually adding the Device to a Z-Wave network
-
Manually removing the Device from a Z-Wave network
-
Factory Reset the Device
Specifications
Power supply |
110-240 V AC / 24-48 V DC / |
Power consumption |
< 0.3 W |
Max. switching voltage AC |
240 V |
Max. switching current AC |
16 A |
Max. switching voltage DC |
30 V |
Max. switching current DC |
10 A |
Overheating protection |
Yes |
Distance |
Up to 40 m indoors (131 ft.) (depends on local condition) |
Z-Wave® repeater |
Yes |
CPU |
Z-Wave® S800 |
Z-Wave® frequency bands |
868,4 MHz; 865,2 MHz; 869,0 MHz; 921,4 MHz; 908,4 MHz; 916 MHz; 919,8 MHz; 922,5 MHz; 919,7-921,7-923,7 MHz; |
Maximum radio frequency |
< 25 mW |
Size (H x W x D) |
37x42x16 ±0.5 mm / 1.46x1.65x0.63 ±0.02 in |
Weight |
26 g / 0.92 oz. |
Mounting |
Wall console |
Screw terminals max. torque |
0.4 Nm / 3.5 lbin |
Conductor cross section |
0.5 to 1.5 mm² / 20 to 16 AWG |
Conductor stripped length |
5 to 6 mm / 0.20 to 0.24 in |
Shell material |
Plastic |
Color |
Blue |
Ambient temperature |
-20°C to 40°C / -5°F to 105°F |
Humidity |
30% to 70% RH |
Max. altitude |
2000 m / 6562 ft |
Basic wiring diagram
Opens image in full screenOpen AC power supply
|
Opens image in full screenOpen 24 - 48 VDC power supply
|
Opens image in full screenOpen 12 VDC power supply
|
Legend
Terminals |
|
Cables |
|
---|---|---|---|
N |
Neutral terminal |
N |
Neutral wire |
L |
Live terminal (110–240 V AC) |
L |
Live (110 - 240 VAC) wire |
SW |
Switch/push-button input terminal (controlling O) |
+ |
12 / 24 - 48 VDC positive wire |
I |
Load circuit input terminal |
GND |
12 / 24 - 48 VDC ground wire |
O |
Load circuit output terminal |
|
|
12V+ |
12 V DC positive terminal |
|
|
+ |
24 - 48 VDC positive terminal |
|
|
Ʇ |
12 / 24 - 48 VDC ground terminal |
|
Z-Wave® Important disclaimer
Z-Wave® wireless communication may not always be 100% reliable. This Device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the Device is not recognized by your gateway or appears incorrectly, you may need to change the Device type manually and ensure that your gateway supports Z-Wave Plus® multi-level devices.
Troubleshooting
For troubleshooting please visit our support portal: Support
Compatibility
Wave 1 |
functions - reports |
||
Gateway |
On/Off |
SW On/Off |
Notes |
Home Assistant |
|
||
Fibaro HC 3 / Z-Wave engine 3 |
|
||
Homey |
|
||
Homee Cube Gen 7 |
|
||
Homee Cube Gen 5 |
|
||
SmartThings |
|||
Jeedom |
|
||
Hubitat |
|
||
Notes |
|
Legend |
||||
Symbol |
State |
|||
Working / Possible |
||||
❌ |
Not Working / Not Possible |
|||
P |
Partially |
|||
N/T |
Not Tested |
|||
TBD |
To be done |
Function |
Meaning |
---|---|
On/Off |
tested if device respond to the app UI On/Off command |
SW On/Off |
tested if device reports On/Off changes by SW input |
Watts |
tested if Watts are reported (unsolicited) |
kWh |
tested if kWh are reported (unsolicited) |
Up/Down |
tested if device respond to the app UI Up/Down command |
SW Up/Down |
tested if device reports Up/Down changes by SW input |
Slats |
tested if the slats respond to the app UI command |
SW Slats |
tested if the slats report the changes done by SW |
Gateway guides
You may find useful guides on gateways in the Z-Wave Shelly Knowledge base.
Compliance
Wave 1 multilingual EU declaration of conformity.pdf
Wave 1 UK PSTI ACT Statement of compliance.pdf
Printed User Guide
Wave_1_multilang_2023_print_V11.pdf