14 дней на возврат оборудованияWave 2PM (EU)
Device identification
Device name: Wave 2PM
EU Part number/Ordering Code: QNSW-002P16EU
USA Part number/Ordering Code: QNSW-002P16US
Z-Wave Product type ID: 0x0002
Z-Wave Product ID: 0x0081
Z-Wave Manufacturer: Shelly Europe Ltd.
Z-Wave Manufacturer ID: 0x0460
Terminology
-
Device - In this document, the term “Device” is used to refer to the Wave 2PM device.
-
Gateway - A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
-
S button - The Z-Wave® Service button, which is located on Z-Wave® devices and is used for various functions such as adding (inclusion), removing (exclusion), and resetting the device to its factory default settings. The term "S button" is used in this document.
Short description
The Wave 2PM (Device) is a single product that enables remote control of two electrical devices such as bulbs, ceiling fans, and IR heaters. It switches (on/off) two independent loads and measures their power consumption separately and in total. The Device is compatible with switches (default) and push-buttons.
Switch connected to input terminal SW (SW1)
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O (O1) to the opposite state - ON, OFF, ON, etc.
-
Change switch position once: Change the state of the output state O (O1) to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
-
Change switch position twice: If the delay between first in second click is less then 500ms, this is interpreted as Change switch position twice. Send command to the associated devices (dimmers, shutters,….) in associated groups 2 and 3 (check chapter Z-Wave Association)
Switch connected to input terminal SW2
If the SW (SW1) is configured as a switch (default), each toggle of the switch will change the output state O2 to the opposite state - ON, OFF, ON, etc.
-
Change switch position once: Change the state of the output state O2 to the opposite one and send command to the associated devices in associated groups 2 and 3 (check chapter Z-Wave Association)
-
Change switch position twice: If the delay between first in second click is less then 500ms, this is interpreted as Change switch position twice. Send command to the associated devices (dimmers, shutters,….) in associated groups 2 and 3 (check chapter Z-Wave Association)
Main applications
-
Residential
-
MDU (Multi Dwelling Units - apartments, condominiums, hotels, etc.)
-
Light commercial (small office buildings, small retail/restaurant/gas station, etc.)
-
Government/municipal
-
University/college
Integrations
Shelly Qubino Wave devices are developed on the world's leading technology for smart homes – Z-Wave.
This means Shelly Qubino Wave works with all certified gateways supporting Z-Wave communication protocol.
To make sure the functions of Shelly Qubino Wave products are supported on your gateway, we are regularly executing compatibility tests of our devices with different Z-Wave gateways.
Simplified internal schematics
Device electrical interfaces
Inputs
-
2 switch/button input on screw terminal
-
3 power supply inputs on screw terminals: N (+) and L (Ʇ)
Outputs
-
2 relay output with power measurement on screw terminal
Connectivity
Z-Wave - Unsecure, S0 Security, S2 Unauthenticated Security, S2 Authenticated Security
Safety features
Overheat protection
-
switch off its own relay
-
sends the Notification Report to the Gateway (Overheat detected)
-
the led lights react as specified above (check blinking mode for Overheat detected)
Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: The Overheat protection is always active and cannot be disabled.
Additional description above under chapter Notification for Overheat detected.
Over-current Protection
Device has internal Over-current protection. If the current exceeds 16A+10% (Max switching current +10%) for more than 5s, the Device will:
-
switch off its own relay
-
sends the Notification Report to the Gateway (Over-current detected)
-
the led lights react as specified above (check blinking mode for Over-current detected)
Any of next activities reset this alarm: power cycle, short press on S button, press any switch-push button connected to any SW (SW, SW1, SW2, …) terminal.
NOTE: The Over-current protection is always active and cannot be disabled.
Additional description above under chapter Notification for Over-current detected.
Supported load types
-
Resistive (incandescent bulbs, heating devices)
-
Capacitive (capacitor banks, electronic equipment, motor start capacitors)
-
Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
User interface
S button and operating modes
-
Normal mode
-
Setting in progress mode
-
Setting mode (with S button)
-
Settings mode is required to start desired procedure for example: adding (inclusion), removing (exclusion), factory reset etc. It has a limited time of operation. After the procedure in Setting mode is concluded, the Device goes automatically into Normal mode.
-
Entering to Setting mode:
-
Quickly press and hold the S button on the Device until the LED turns solid blue
-
An additional quick press on the S button means menu change in infinite loop
-
Menu LED status has a timeout of 10s before entering again into Normal state
-
-
S button’s functions
-
Manually adding the Device to a Z-Wave network
-
Manually removing the Device from a Z-Wave network
-
Factory Reset the Device
Specifications
Power supply |
110-240 V AC / 24 V DC +/- 10% |
Power consumption |
< 0.3 W |
Power measurement [W] |
Yes |
Max switching voltage AC |
240 V |
Max switching current AC |
10 A per channel, 16 A total, 18 A total peak |
Max switching voltage DC |
30 V |
Max switching current DC |
10 A |
Overheating protection |
Yes |
Over-current protection |
Yes |
Over-voltage protection |
Yes |
Distance |
up to 40 m indoors (131 ft.) (depends on local condition) |
Z-Wave® repeater: |
Yes |
CPU |
Z-Wave® S800 |
Z-Wave® frequency bands: |
868,4 MHz; 865,2 MHz; 869,0 MHz; 921,4 MHz; 908,4 MHz; 916 MHz; 919,8 MHz; 922,5 MHz; 919,7- 921,7-923,7 MHz; 868,1 MHz; 920,9 MHz |
Maximum radio frequency power transmitted in frequency bend(s) |
< 25 mW |
Size (H x W x D) |
37 x 42 x 16 ± 0.5 mm / 1.46 x 1.65 x 0.63 ± 0.02 in |
Weight |
29g |
Mounting |
Wall console |
Screw terminals max torque |
0.4 Nm / 3.5 lbin |
Conductor cross section |
0.5 to 1.5 mm² / 20 to 16 |
Conductor stripped length |
5 to 6 mm / 0.20 to 0.24 in |
Shell material |
Plastic |
Colour |
Black |
Ambient temperature |
-20°C to 40°C / -5°F to 105°F |
Humidity |
30% to 70% RH |
Max. altitude |
2000 m / 6562 ft. |
Basic wiring diagram
Opens image in full screenOpen Fig.1 |
Opens image in full screenOpen Fig. 2
|
Opens image in full screenOpen Fig. 3 |
Opens image in full screenOpen Fig. 4 |
Legend
Terminals |
|
Wires |
|
---|---|---|---|
N |
Neutral terminal |
N |
Neutral wire |
L |
Live terminal (110–240 V AC) |
L |
Live (110 - 240 V AC) wire |
SW 1 |
Switch/push-button input terminal (controlling O1) |
+ |
24 V DC positive wire |
SW 2 |
Switch/push-button input terminal (controlling O2) |
GND |
24 V DC ground wire |
O1 |
Load circuit 1 output terminal |
|
|
O2 |
Load circuit 2 output terminal |
|
|
+ |
24 V DC positive terminal |
|
|
Ʇ |
24 V DC ground terminal |
|
Z-Wave® Important disclaimer
Z-Wave® wireless communication may not always be 100% reliable. This Device should not be used in situations in which life and/or valuables are solely dependent on its functioning. If the Device is not recognised by your gateway or appears incorrectly, you may need to change the Device type manually and ensure that your gateway supports Z-Wave Plus™ multi-level devices.
Troubleshooting
For troubleshooting please visit our support portal: https://support.shelly.cloud/
Compatibility with gateways
Wave 2PM |
functions - reports |
|||||||
Gateway |
On/Off 1 |
On/Off 2 |
SW 1 On/Off |
SW 2 On/Off |
W 1 |
W 2 |
kWh |
Notes |
Home Assistant |
|
|||||||
Fibaro HC 3 / Z-Wave engine 3 |
|
|||||||
Homey |
Troubles with reports can be solved with this solution. |
|||||||
Homee Cube Gen 7 |
|
|||||||
Homee Cube Gen 5 |
P |
P |
P |
P |
P |
P |
P |
*1 |
SmartThings |
|
|||||||
Jeedom |
|
|||||||
Hubitat |
❌ |
❌ |
❌ |
❌ |
❌ |
❌ |
❌ |
|
Notes |
*1 - The device is configured as a single-channel device, featuring a singular switch within the application interface that enables control over both outputs simultaneously. |
Legend |
||||
Symbol |
State |
|||
Working / Possible |
||||
❌ |
Not Working / Not Possible |
|||
P |
Partially |
|||
N/T |
Not Tested |
|||
TBD |
To be done |
Function |
Meaning |
---|---|
On/Off |
tested if device respond to the app UI On/Off command |
SW On/Off |
tested if device reports On/Off changes by SW input |
Watts |
tested if Watts are reported (unsolicited) |
kWh |
tested if kWh are reported (unsolicited) |
Up/Down |
tested if device respond to the app UI Up/Down command |
SW Up/Down |
tested if device reports Up/Down changes by SW input |
Slats |
tested if the slats respond to the app UI command |
SW Slats |
tested if the slats report the changes done by SW |
Gateway guides
You may find useful guides on gateways in the Z-Wave Shelly Knowledge base.
Compliance
Wave 2PM multilingual EU declaration of conformity.pdf
Wave 2PM UK PSTI ACT Statement of compliance.pdf
Printed User Guide
Wave_2PM_multilang_2023_print_V4.pdf
Техническая поддержка
Способы оплаты
Доставка
Оптовые продажи
Наш блог
Введите известный Вам промокод и цены будут автоматически снижены
Будьте в курсе новинок и специальных предложений